Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types
Ji Young Lee, Sung Hwa Hong, Il Joon Moon, Eun Yeon Kim, Eunjoo Baek, Hye Yoon Seol, Sihyung Kang
J Audiol Otol. 2019;23(3):145-152.   Published online 2019 Jul 10     DOI: https://doi.org/10.7874/jao.2019.00164
Citations to this article as recorded by Crossref logo
Comparison of Slim Perimodiolar and Slim Straight Electrode Arrays in Pediatric Cochlear Implantation: A Radiologic, Electrophysiological, and Audiological Study
Maria-Pia Tuset, Emilie Bois, Nathalie Noel-Petroff, Natacha Teissier, Thierry Van Den Abbeele, Charlotte Benoit
Otology & Neurotology.2026; 47(3): 447.     CrossRef
Translating clinical evidence into real-world experience with the Slim Modiolar electrode (CI632) in China: patient and surgeon perspectives on hearing performance and satisfaction
Xiguang Tian, Jingwe Cui, Shunnian Zeng, Daogui Zhu, Chenjiong Wu, Xiao Ao, Xinyu Luo
Frontiers in Audiology and Otology.2026;[Epub]     CrossRef
Intraoperative detection of cochlear implant electrode tip fold-over using transimpedance matrix (TIM) measurements: a comparative study with X-ray imaging
Jiahao Liu, Maojin Liang, Yiqing Zheng, Yajing Wang
Acta Oto-Laryngologica.2026; 146(4): 416.     CrossRef
Micro‐CT Evaluation of Robot‐Assisted Insertion of CI632 Implant in Human Cadaveric Temporal Bones
Sean C. Sheppard, Hannah Daoudi, Resul Ekici, Daniele De Seta, Evelyne Ferrary, Isabelle Mosnier, Ghizlene Lahlou, Thierry Van Den Abbeele, Renato Torres, Yann Nguyen
The Laryngoscope.2026; 136(9): 3946.     CrossRef
Short‐ Versus Long‐Term Hearing Preservation and Speech Recognition Outcomes in Precurved and Straight Electrode Arrays
Lily V. Den Hartog, Andrew W. Liu, Divya A. Chari
OTO Open.2026;[Epub]     CrossRef
Cochlear implant revisions: a 10-year review of the victorian cochlear implant program
Ayden Tchernegovski, Jaime Leigh, Richard Dowell, Robert Briggs, Jean-Marc Gerard
Australian Journal of Otolaryngology.2026; 9: 24.     CrossRef
In silico framework for benchmarking optogenetic hearing restoration
Lakshay Khurana, Petr Nejedly, Yixuan Zhang, Daniel J Jagger, Waldo Nogueira, Tobias Moser, Lukasz Jablonski
Journal of Neural Engineering.2026; 23(5): 056033.     CrossRef
Long-Term Impedance Trends Over 10 Years Following Cochlear Implantation: A Retrospective Comparative Analysis
Jianhang Deng, Martin Koch, Matthias Bornitz, Sijia Zhai, Marcus Neudert, Till Moritz Essinger
Journal of Otolaryngology - Head & Neck Surgery.2026;[Epub]     CrossRef
Electrode–Modiolar Distance as a Determinant of Cochlear Implant Performance: A Systematic Review and Meta‐Analysis
Nidhin Das K, Vidhu Sharma, Siddharth Manoj, Amit Goyal
Clinical Otolaryngology.2026;[Epub]     CrossRef
Characteristics of Medial and Lateral Wall Cochlear Implant Arrays Demonstrated with Cone Beam CT and Evoked Electrical Auditory Brainstem Responses
Fadwa Alnafjan, Melville J. da Cruz, Catherine M. McMahon
Otology & Neurotology.2025; 46(4): 364.     CrossRef
Assessing Array-Type Differences in Cochlear Implant Users Using the Panoramic ECAP Method
Charlotte Garcia, Robert P. Carlyon
Ear & Hearing.2025; 46(5): 1355.     CrossRef
Comparison of Two Precurved Cochlear Implant Electrode Arrays from the Same Manufacturer: Electrophysiological Differences with Possible Implications for Fitting and Battery Life
Khalil Rafiqi, Kristoffer Foldager Jørgensen, Anders Britze
Audiology and Neurotology.2025; 31(2): 91.     CrossRef
Simulated auditory nerve response evoked by lateral-wall and peri-modiolar electrode arrays inserted in scala tympani or scala vestibuli
Cornelia Wenger, Andreas Fellner, Frank Rattay
Frontiers in Neuroscience.2025;[Epub]     CrossRef
Effect of Return Electrode Placement at Apical Cochleostomy on Current Flow With a Cochlear Implant
David M. Landsberger, Christopher J. Long, Jonathon R. Kirk, Natalia Stupak, J. Thomas Roland
Ear & Hearing.2024; 45(2): 511.     CrossRef
Comparison of Speech Perception Performance According to Prosody Change Between People With Normal Hearing and Cochlear Implant Users
Eun Yeon Kim, Hye Yoon Seol
Journal of Audiology and Otology.2024; 28(2): 119.     CrossRef
A Case of Superficial Siderosis That Underwent Cochlear Implantation
Yuki Kubo, Masahiro Matsumoto, Hideaki Ogita, Juichi Ito, Masako Nakai, Haruka Tsutsumi, Mari Kitanaka, Shinji Takebayashi, Kiyohiro Fujino
Practica Oto-Rhino-Laryngologica.2024; 117(5): 397.     CrossRef
Evaluation of a Slim Modiolar Electrode Array: A Temporal Bone Study
Leena Asfour, Frank Risi, Claudiu Treaba, Jonathon Kirk, J. Roland Thomas
Otology & Neurotology.2024; 45(8): 870.     CrossRef
Influence of the Electrode Array Design on Incidence of Vertigo Symptoms and Vestibular Function After Cochlear Implantation
Farnaz Matin, Caroline Krueger, Emilio Avallone, Willi Rossberg, Alexey Demyanchuk, Annette Guenther, Thomas Lenarz, Anke Lesinski-Schiedat
Ear, Nose & Throat Journal.2023; 102(11): 701.     CrossRef
Cochlear implant electrode array tip-foldover detection by electrode voltage telemetry
Marc Leblans, Andrzej Zarowski, Andrzej Molisz, Joost van Dinther, Janne Dedeyne, Bob Lerut, Rudolf Kuhweide, Erwin Offeciers
Cochlear Implants International.2023; 24(2): 95.     CrossRef
3D-localisation of cochlear implant electrode contacts in relation to anatomical structures from in vivo cone-beam computed tomography
Fergio Sismono, Marc Leblans, Lucia Mancini, Alessio Veneziano, Franco Zanini, Joris Dirckx, Anja Bernaerts, Bert de Foer, Erwin Offeciers, Andrzej Zarowski
Hearing Research.2022; 426: 108537.     CrossRef
Stimulating the Cochlear Apex Without Longer Electrodes: Preliminary Results With a New Approach
David M. Landsberger, Natalia Stupak, Emily R. Spitzer, Lavin Entwisle, Laurel Mahoney, Susan B. Waltzman, Sean McMenomey, David R Friedmann, Mario A. Svirsky, William Shapiro, J. Thomas Roland
Otology & Neurotology.2022; 43(5): e578.     CrossRef
Novel Impedance Measures as Biomarker for Intracochlear Fibrosis
Marc Leblans, Fergio Sismono, Filiep Vanpoucke, Joost van Dinther, Bob Lerut, Rudolf Kuhweide, Erwin Offeciers, Andrzej Zarowski
Hearing Research.2022; 426: 108563.     CrossRef
Recent Advances in Cochlear Implant Electrode Array Design Parameters
Yavuz Nuri Ertas, Derya Ozpolat, Saime Nur Karasu, Nureddin Ashammakhi
Micromachines.2022; 13(7): 1081.     CrossRef
Is the spread of excitation width correlated to the speech recognition in cochlear implant users?
Juliana Coutinho da Silva, Maria Valéria Schmidt Goffi-Gomez, Ana Tereza Magalhães, Robinson Koji Tsuji, Ricardo Ferreira Bento
European Archives of Oto-Rhino-Laryngology.2021; 278(6): 1815.     CrossRef
Effect of age, electrode array, and time on cochlear implant impedances
Sandra Velandia, Diane Martinez, Stefania Goncalves, Stefanie Pena, Esperanza Bas, Liliana Ein, Sandra Prentiss, Fred Telischi, Simon Angeli, Christine T. Dinh
Cochlear Implants International.2020; 21(6): 344.     CrossRef
Dendritic Degeneration of Human Auditory Nerve Fibers and Its Impact on the Spiking Pattern Under Regular Conditions and During Cochlear Implant Stimulation
Amirreza Heshmat, Sogand Sajedi, Lejo Johnson Chacko, Natalie Fischer, Anneliese Schrott-Fischer, Frank Rattay
Frontiers in Neuroscience.2020;[Epub]     CrossRef