| J Audiol Otol > Epub ahead of print |
|
Conflicts of Interest
Sarah Rahmat, a contributing editor of the Journal of Audiology and Otology, was not involved in the editorial evaluation or decision to publish this article. All remaining authors have declared no conflicts of interest.
Author Contributions
Conceptualization: Ahmad Aidil Arafat Dzulkarnain. Data curation: Fatin Nabilah Jamal, Ahmad Aidil Arafat Dzulkarnain. Formal analysis: Fatin Nabilah Jamal, Ahmad Aidil Arafat Dzulkarnain, Sarah Rahmat. Investigation: Ahmad Aidil Arafat Dzulkarnain, Fatin Nabilah Jamal, Fatin Amira Shahrudin, Sarah Rahmat. Methodology: Ahmad Aidil Arafat Dzulkarnain. Project administration: Ahmad Aidil Arafat Dzulkarnain, Fatin Nabilah Jamal, Ramli Musa, Nadzirah Ahmad Basri, Shahrul Na’im Sidek. Software: Mohd Zulfaezal Che Azemin, Fatin Nabilah Jamal, Fatin Amira Shahrudin. Supervision: Ahmad Aidil Arafat Dzulkarnain, Sarah Rahmat. Validation: Ahmad Aidil Arafat Dzulkarnain, Fatin Nabilah Jamal, Nadzirah Ahmad Basri, Shahrul Na’im Sidek, Hazlina Md Yusof, Siti Rafiah Abd. Hamid. Visualization: Fatin Nabilah Jamal. Writing—original draft: Ahmad Aidil Arafat Dzulkarnain. Writing—review & editing: Ahmad Aidil Arafat Dzulkarnain. Approval of final manuscript: all authors.
Acknowledgments
The authors would like to acknowledge staff from the tertiary hospital and Department of Audiology and Speech-Language Pathology, International Islamic University Malaysia for their assistance in the data collection process. Special appreciation is extended to the parents of the participants who consented to their children’s involvement in this study.
| Group | Pre | Post | p | Effect size |
|---|---|---|---|---|
| Control (n=5) | 2.25±1.13 | 1.87±2.34 | 0.51 | 0.21 |
| Quranic recitation+WMT (n=5) | 1.44±2.34 | 1.62±2.00 | 0.77 | 0.08* |
| Waterfall+WMT (n=5) | 0.76±1.92 | 1.92±1.38 | 0.35 | 0.69* |
| White noise+WMT (n=6) | -2.28±2.00 | 2.18±1.66 | 0.04* | 2.42* |
Values are presented as mean±standard deviation. The Control group crossed over to Quranic+WMT after the initial 4 weeks; therefore, its post-intervention scores are identical to the pre-intervention scores of the crossover Quranic+WMT group, as both come from the same participants at the same time point. TEOAE, transient evoked otoacoustic emissions; WMT, working memory training.
| Frequency |
RM ANOVA |
Control |
Waterfall+WMT |
White noise+WMT |
Quranic recitation+WMT |
|||||
|---|---|---|---|---|---|---|---|---|---|---|
| p | Effect size | p | Effect size | p | Effect size | p | Effect size | p | Effect size | |
| 1 kHz | 0.03 | 0.57 | 0.67 | 0.01 | 0.12 | 0.13* | 0.30 | 0.06* | 0.34 | 0.05* |
| 1.4 kHz | 0.82 | 0.01 | 0.79 | 0.01 | 0.05 | 0.20* | 0.67 | 0.01 | ||
| 2 kHz | 0.64 | 0.01 | 0.57 | 0.02 | 0.01 | 0.33* | 0.75 | 0.01 | ||
| 2.8 kHz | 0.92 | 0.01 | 0.55 | 0.02 | 0.05 | 0.20* | 0.64 | 0.01 | ||
| 4 kHz | 0.65 | 0.01 | 0.58 | 0.02 | 0.04 | 0.22* | 0.09 | 0.15* | ||
| Frequency | Group | Group pair | p | Effect size |
|---|---|---|---|---|
| Gain 1 kHz | Quranic recitation+WMT | Waterfall+WMT | 0.08 | 1.16* |
| White noise+WMT | 0.17 | 0.95* | ||
| Waterfall+WMT | White noise+WMT | 0.64 | 0.26 | |
| Gain 1.4 kHz | Quranic recitation+WMT | Waterfall+WMT | 0.91 | 0.07 |
| White noise+WMT | 0.11 | 0.93* | ||
| Waterfall+WMT | White noise+WMT | 0.13 | 0.81* | |
| Gain 2 kHz | Quranic recitation+WMT | Waterfall+WMT | 0.86 | 0.11 |
| White noise+WMT | 0.11 | 0.94* | ||
| Waterfall+WMT | White noise+WMT | 0.15 | 0.83* | |
| Gain 2.8 kHz | Quranic recitation+WMT | Waterfall+WMT | 0.45 | 0.48 |
| White noise+WMT | 0.32 | 0.67* | ||
| Waterfall+WMT | White noise+WMT | 0.09 | 0.85* | |
| Gain 4 kHz | Quranic recitation+WMT | Waterfall+WMT | 0.12 | 0.82* |
| White noise+WMT | 0.85 | 0.14 | ||
| Waterfall+WMT | White noise+WMT | 0.07 | 0.97* |

![]() |
![]() |